Moxa

MDR Power Supply Series

40/60 W slim form factor power supplies for DIN-rail mounted products

MDR Power Supply Series

Features and Benefits

  • High inrush current protection
  • 24 VDC power output
  • -20 to 70°C operating temperature range
  • 85 to 264 VAC or 120 to 370 VDC input

Certifications

  • CE
  • UL Listed

Introduction

The MDR Power Supply Series supports inrush current protection of 30 A at 115 VAC and 60 A at 230 VAC. The series has an operating temperature range of -20 to 70°C and a three year warranty, which ensures suitability for operating in harsh environments. In addition, the MDR Series has passed a 100% full load burn-in test, is UL/CUL listed, TÜV/CB certified, and CE marked. There are also models available with output ratings from 40 W to 60 W with 24 VDC output.

Models in this series (2)

MDR-40-24MDR-60-24
Input Voltage85 to 264 VAC 120 to 370 VDC85 to 264 VAC 120 to 370 VDC
Output Voltage24 VDC24 VDC
Output Wattage40 W60 W
Operating Temp.-20 to 70°C-20 to 70°C
Add to Quote View Bag Buy from distributors (for USA only)Add to Quote View Bag Buy from distributors (for USA only)

Specifications

Shown for MDR-40-24. Per-model differences are listed in the selection grid above.

Output Power Parameters

Wattage
40 W
Voltage
24 VDC
Current Rating
0 to 1.7 A
Ripple and Noise
150 mVp-p
Voltage Adjustment Range
24 to 30 VDC
Setup/Rise Time at Full Load
500 ms, 30 ms at 115 VAC 500 ms, 30 ms at 230 VAC
Typical Hold Up Time at Full Load
20 ms at 115 VAC 50 ms at 230 VAC

Input Power Parameters

Voltage Range
85 to 264 VAC (47 to 63 Hz) 120 to 370 VDC
Typical Efficiency
88%
Typical Current
0.7 A @ 230 VAC, 1.1 A @ 115 VAC
Typical Current (cold start)
60 A @ 230 VAC, 30 A @ 115 VAC

Overload Protection

Rated Output Power
105 to 150%
Protection Type
Constant current limiting, recovers automatically after fault condition is removed

Overvoltage Protection

Overvoltage Range
31.2 to 36 V
Protection Type
Shut down operating voltage, repower on to recover

Physical Characteristics

Dimensions
40 x 90 x 100 mm (1.57 x 3.54 x 3.94 in)
Weight
260 g (0.57 lb)

Environmental Limits

Operating Temperature
-20 to 70°C (-4 to 158°F)
Max. Operating Temperature at Full Load
60°C
Ambient Relative Humidity
20 to 90% (non-condensing)

Standards and Certifications

Safety
UL 508 EN 62368-1 IEC 62368-1
EMC
EN 55032/35 EN 61000-3-2 Class A EN 61000-3-3 EN IEC 61204-3 EN IEC 61000-6-2
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV IEC 61000-4-5 Surge: Power: 4 kV IEC 61000-4-6 CS: 0.15 kHz to 80 MHz: 10 Vrms IEC 61000-4-8 PFMF: 30 A/m IEC 61000-4-11

Warranty

Warranty Period
3 years
Details
See www.moxa.com/warranty

Resources

Need pricing on the MDR Power Supply Series?

Tell us quantities and we'll come back with a quote.

Get a Quote