ICF-1150I-M-SC-IEX
ICF-1150 SeriesIndustrial RS-232/422/485 to fiber converters
- 3-way communication: RS-232, RS-422/485, and fiber
- Rotary switch to change the pull high/low resistor value
- Extends RS-232/422/485 transmission up to 40 km with single-mode or 5 km with multi-mode
- -40 to 85°C wide-temperature range models available
- C1D2, ATEX, and IECEx certified for harsh industrial environments
Certifications UL Listed · CE · FCC
Ships from and sold by A5 IT, an authorized Moxa reseller.
Specifications
Serial Interface
- No. of Ports
- 2
- Serial Standards
- RS-232 RS-422 RS-485
- Baudrate
- 50 bps to 921.6 kbps (supports non-standard baudrates)
- Flow Control
- ADDC (automatic data direction control) for RS-485
- Connector
- 5-pin terminal block Multi-mode SC connector
- Isolation
- 2 kV (I models)
- Optical Fiber
- Read more Low-Speed Fiber Module Multi-Mode Single-Mode Fiber Cable Requirements 50/125 µm, 800 MHz G.652 62.5/125 µm, 500 MHz Typical Distance 5 km 40 km Wavelength Typical (nm) 850 1310 TX Range (nm) 840 to 860 1290 to 1330 RX Range (nm) 800 to 900 1100 to 1650 Optical Power TX Range (dBm) 0 to -8 0 to -8 RX Range (dBm) 0 to -25 0 to -25 Link Budget (dB) 15 20 Dispersion Penalty (dB) 1 1 Note: When using a power meter to measure the fiber TX power, set the baudrate to 9,600 bps and send data (00, ..., 0h) to the serial converter’s serial port.
- Pull High/Low Resistor for RS-485
- 150 kilo-ohm, 10 kilo-ohm, 4.7 kilo-ohm, 3.3 kilo-ohm, 1 kilo-ohm, 909 ohm, 822 ohm, 770 ohm, 500 ohm, 485 ohm
- RS-485 Data Direction Control
- ADDC (automatic data direction control)
- Terminator for RS-485
- N/A, 120 ohms, 120 kilo-ohms
Serial Signals
- RS-232
- TxD, RxD, GND
- RS-422
- Tx+, Tx-, Rx+, Rx-, GND
- RS-485-4w
- Tx+, Tx-, Rx+, Rx-, GND
- RS-485-2w
- Data+, Data-, GND
Power Parameters
- Input Current
- 300 mA (max)
- Input Voltage
- 12 to 48 VDC
- No. of Power Inputs
- 1
- Overload Current Protection
- Supported
- Power Connector
- Terminal block
Physical Characteristics
- Housing
- Metal
- IP Rating
- IP30
- Dimensions
- 30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
- Weight
- 330 g (0.73 lb)
- Installation
- DIN-rail mounting
Environmental Limits
- Operating Temperature
- 0 to 60°C (32 to 140°F)
- Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
- EMC
- EN 55032/35
- EMI
- CISPR 32, FCC Part 15B Class A
- EMS
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 4 kV; Signal: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF
- Environmental Testing
- IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-3
- Safety
- UL 61010-2-201
- Vibration
- IEC 60068-2-6
- Hazardous Locations
- UL/cUL Class I Division 2 Groups A/B/C/D ATEX Zone 2 IECEx
MTBF
- Time
- 792,085 hrs
- Standards
- Telcordia (Bellcore), GB
Warranty
- Warranty Period
- 5 years
- Details
- See www.moxa.com/warranty
Documentation
| Name | Type | Version | Date |
|---|---|---|---|
| Datasheet for ICF-1150 Series727.8 KB | Datasheet | v1.6 | Oct 24, 2024 |
| QIG for ICF-1150 Series1.6 MB | QIG | v8.2 | Oct 17, 2022 |
| 2D CAD for ICF-1150-M-SC Model71.2 KB | 2D CAD | — | May 20, 2016 |
| 2D CAD for ICF-1150I-M-ST636.5 KB | 2D CAD | — | May 20, 2016 |
| 2D CAD for ICF-1150-M-SC481.4 KB | 2D CAD | — | May 20, 2016 |
| 2D CAD for ICF-1150-S-SC472.9 KB | 2D CAD | — | May 20, 2016 |
| 2D CAD for ICF-1150-M-ST533.9 KB | 2D CAD | — | May 20, 2016 |
| 2D CAD for ICF-1150I-M-SC500.1 KB | 2D CAD | — | May 20, 2016 |