Moxa
TCC-100I-T

TCC-100I-T

TCC-100/100I Series

Industrial RS-232 to RS-422/485 converters with optional 2 kV isolation

  • RS-232 to RS-422 conversion with RTS/CTS support
  • RS-232 to 2-wire or 4-wire RS-485 conversion
  • 2 kV isolation protection (TCC-100I)
  • Wall mounting and DIN-rail mounting
  • Plug-in terminal block for easy RS-422/485 wiring
  • LED indicators for power, Tx, Rx
  • Wide-temperature model available for -40 to 85°C environments

Certifications UL Listed · CE · FCC

Ships from and sold by A5 IT, an authorized Moxa reseller.

Specifications

Serial Interface

No. of Ports
2
Connector
Terminal block
Serial Standards
RS-232 RS-422 RS-485
Baudrate
50 bps to 921.6 kbps (supports non-standard baudrates)
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
RS-485 Data Direction Control
ADDC (automatic data direction control)
Terminator for RS-485
N/A, 120 ohms, 120 kilo-ohms
Isolation
2 kV (I models)

Serial Signals

RS-232
TxD, RxD, RTS, CTS, GND
RS-422
Tx+, Tx-, Rx+, Rx-, RTS (optional), CTS (optional), GND
RS-485-2w
Data+, Data-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND

Power Parameters

Input Current
144 mA (max)
Input Voltage
12 to 48 VDC
No. of Power Inputs
1
Overload Current Protection
Supported
Power Connector
Terminal block (for DC models)

Physical Characteristics

Housing
Metal
IP Rating
IP30
Dimensions
67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
Weight
148 g (0.33 lb)
Installation
Wall mounting DIN-rail mounting (with optional kit)

Environmental Limits

Operating Temperature
-40 to 85°C (-40 to 185°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)

Standards and Certifications

EMC
EN 55032/35
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF
Safety
UL 60950-1
Vibration
IEC 60068-2-6
Environmental Testing
IEC 60068-2-1 IEC 60068-2-3

MTBF

Time
3,017,857 hrs
Standards
Telcordia (Bellcore), GB

Warranty

Warranty Period
5 years
Details
See www.moxa.com/warranty

Documentation

NameTypeVersionDate
Datasheet for TCC-100/100I Series769.9 KBDatasheetv1.5Dec 04, 2024
Declaration of Conformity for TCC-100I/100I-T296.3 KBDeclarationv1.0May 08, 2024
Declaration of Conformity for TCC-100/100I295.0 KBDeclarationv1.0May 08, 2024
QIG for TCC-100/100I Series2.1 MBQIGv12.2Jan 04, 2022
2D CAD for TCC-100 TOP483.0 KB2D CADMar 27, 2015