Moxa

NPort 5600-DT-G2 Series

8/16-port RS-232/422/485 compact desktop serial device servers

NPort 5600-DT-G2 Series

Features and Benefits

  • 10/100/1000M auto-sensing Ethernet
  • Compact desktop design: 8-port DTS and 16-port slim models available
  • One-click log collection and application analysis for easy troubleshooting
  • Data encryption with secure operation modes for Real COM, TCP Server, TCP Client, Pair Connection, Terminal, and Reverse Terminal
  • Secure Boot only allows Moxa-authorized firmware to run on devices
  • Supports SSL certificate signing by RSA-4096 and ECC-521
  • Compliance with IEC 62443-4-2 Security Level 2 requirements

Certifications

  • UL Listed
  • CE
  • FCC

Introduction

NPort 5600-8-DT-G2 device servers can conveniently and transparently connect up to 16 serial devices to an Ethernet network, allowing you to network your existing serial devices with only basic configuration. You can both centralize management of your serial devices and distribute management hosts over the network. Since the NPort 5600-8-DT-G2 device servers have a slim form factor compared to our other device servers, they are a great choice for applications that need additional serial ports, but for which mounting rails are not available. The device servers also come with one-click log collection and one-click application analyzer for easy troubleshooting.

Models in this series (14)

NPort 5610-8-DT-G2NPort 5610-8-DT-G2-TNPort 5650-8-DT-G2NPort 5650-8-DT-G2-T
Ethernet Interface2 x 10/100/1000M RJ452 x 10/100/1000M RJ452 x 10/100/1000M RJ452 x 10/100/1000M RJ45
No. of Serial Ports8888
Serial StandardsRS-232RS-232RS-232/422/485RS-232/422/485
Serial Interface ConnectorDB9 MaleDB9 MaleDB9 MaleDB9 Male
Serial Interface Isolation
Operating Temp.-10 to 60°C-40 to 75°C-10 to 60°C-40 to 75°C
Add to Quote View BagAdd to Quote View BagAdd to Quote View BagAdd to Quote View Bag
NPort 5650I-8-DT-G2NPort 5650I-8-DT-G2-TNPort 5610-16-DT-J-G2NPort 5610-16-DT-J-G2-T
Ethernet Interface2 x 10/100/1000M RJ452 x 10/100/1000M RJ452 x 10/100/1000M RJ452 x 10/100/1000M RJ45
No. of Serial Ports881616
Serial StandardsRS-232/422/485RS-232/422/485RS-232RS-232
Serial Interface ConnectorDB9 MaleDB9 Male8-pin RJ458-pin RJ45
Serial Interface Isolation2 kV2 kV
Operating Temp.-10 to 60°C-40 to 75°C-10 to 60°C-40 to 75°C
Add to Quote View BagAdd to Quote View BagAdd to Quote View BagAdd to Quote View Bag
NPort 5650-16-DT-J-G2NPort 5650-16-DT-J-G2-TNPort 5610-8-DTS-J-G2NPort 5610-8-DTS-J-G2-T
Ethernet Interface2 x 10/100/1000M RJ452 x 10/100/1000M RJ452 x 10/100/1000M RJ452 x 10/100/1000M RJ45
No. of Serial Ports161688
Serial StandardsRS-232/422/485RS-232/422/485RS-232RS-232
Serial Interface Connector8-pin RJ458-pin RJ4510-pin RJ5010-pin RJ50
Serial Interface Isolation
Operating Temp.-10 to 60°C-40 to 75°C-10 to 60°C-40 to 75°C
Add to Quote View BagAdd to Quote View BagAdd to Quote View BagAdd to Quote View Bag
NPort 5650-8-DTS-J-G2NPort 5650-8-DTS-J-G2-T
Ethernet Interface2 x 10/100/1000M RJ452 x 10/100/1000M RJ45
No. of Serial Ports88
Serial StandardsRS-232/422/485RS-232/422/485
Serial Interface Connector10-pin RJ5010-pin RJ50
Serial Interface Isolation
Operating Temp.-10 to 60°C-40 to 75°C
Add to Quote View BagAdd to Quote View Bag

Specifications

Shown for NPort 5610-16-DT-J-G2. Per-model differences are listed in the selection grid above.

Ethernet Interface

10/100/1000BaseT(X) Ports (RJ45 connector)
2 Auto MDI/MDI-X connection
Magnetic Isolation Protection
1.5 kV (built-in)

Ethernet Software Features

Configuration Options
Web Console (HTTPS) Windows Utility Device Search Utility (DSU) MCC Tool Serial Console
Management
ARP DHCP Client DNS HTTPS ICMP IPv4/IPv6 SMTP SMTPS SNMPv1/v2c/v3 SNTP TCP/IP UDP WINS
Windows Real COM Drivers
Windows 11, 10, 8.1, 8, and 7 Windows Server 2022, 2019, 2016, 2012 R2, 2012, and 2008 R2
Linux Real TTY Drivers
Kernel versions 6.x, 5.x, and 4.x
Fixed TTY Drivers
macOS versions: 14, 13, 12, and 11
Arm®-based Platform Support
Windows 11 Linux Kernel 6.x, 5.x and 4.x macOS 14, 13, 12 and 11
Virtual Machine
VMWare ESXi (Windows 11/10/8.1/8/7 & Linux 6.x, 5.x, and 4.x) VMware Fusion (Windows on macOS 14, 13, 12, and 11) Parallels Desktop (Windows on macOS 14, 13, 12, and 11)
Time Management
SNTP Client
MIB
MIB-II RFC1213, RFC1317 Private MIB

Security Functions

Root of Trust
Secure Boot True Random Number Generator (TRNG)
Authentication
Local database (RBAC support)
Encryption
HTTPS: ECC-256, ECC-384, ECC-521, RSA-1024, RSA-2048, RSA-3072, RSA-4096, AES-128, AES-256, CHACHA20, SHA-256, SHA-384, HMAC SNMPv3: AES-128, SHA-256, SHA-384 Secure OP mode: HTTPS: ECC-256, ECC-384, ECC-521, RSA-1024, RSA-2048, RSA-3072, RSA-4096, AES-128, AES-256, CHACHA20, SHA-256, SHA-384, HMAC Config Import/Export: AES-256, SHA-256, HMAC
Security Protocols
HTTPS (TLS 1.2) SNMPv3

Serial Interface

Connector
NPort 5600-8-DT-G2 models: DB9 male NPort 5600-16-DT-J-G2 models: 8-pin RJ45 NPort 5600-8-DTS-J-G2 models: 10-pin RJ50
No. of Ports
NPort 5600-8-DT-G2/5600-8-DTS-J-G2 models: 8 NPort 5600-16-DT-G2 models: 16
Serial Standards
NPort 5610-DT-G2/5610-DTS-G2 models: RS-232 NPort 5650-DT-G2/5650-DTS-G2 models: RS-232, RS-422, RS-485
Secure Operation Modes
Secure Pair Connection Secure Real COM Secure TCP Client Secure TCP Server
Standard Operation Modes
Disabled Pair Connection Real COM RFC2217 TCP Client TCP Server UDP
Bitrate
50 bps to 921.6 kbps (supports non-standard baudrates)
Data Bits
5, 6, 7, 8
Stop Bits
1, 1.5, 2
Parity
None, Even, Odd, Space, Mark
Flow Control
None RTS/CTS DTR/DSR XON/XOFF
RS-485 Data Direction Control
Automatic Data Direction Control (ADDC)
Terminator for RS-485
120 ohms
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms

Serial Signals

RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
Data+, Data-, GND

Power Parameters

No. of Power Inputs
1
Input Current
800 mA (max.)
Input Voltage
12 to 48 VDC
Reverse Polarity Protection
Supported
Source of Input Power
Terminal block

Reliability

Automatic Reboot Trigger
Built-in WDT
Alert Tools
Built-in buzzer and RTC (real-time clock)

Physical Characteristics

Housing
Metal
Dimensions (without ears)
NPort 5600-DT-G2 models: 197 x 125 x 44 mm (7.76 x 4.92 x 1.73 in) NPort 5600-DTS-G2 models: 210 x 95 x 25 mm (8.27 x 3.74 x 0.98 in)
Weight
NPort 5600-8-DT-G2 models: 880 g (1.94 lbs) NPort 5600-16-DT-J-G2 models: 875 g (1.93 lbs) NPort 5600-8-DTS-J-G2 models: 610 g (1.34 lbs)
Weight (including package)
NPort 5600-8-DT-G2 models: 1,315 g (2.90 lbs) NPort 5600-16-DT-J-G2 models: 1,285 g (2.83 lbs) NPort 5600-8-DTS-J-G2 models: 925 g (2.04 lbs)
Installation
Desktop Wall mounting DIN-rail mounting (with optional kit)

Environmental Limits

Operating Temperature
Standard models: -10 to 60°C (14 to 140°F) Wide temp. models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included)
-40 to 75°C (-40 to 167°F)
Ambient Relative Humidity
5 to 95% (non-condensing)

Standards and Certifications

EMC
EN 55032/35
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 0.5 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-11
Safety
IEC 62368-1 UL 62368-1 EN 62368-1
Vibration
IEC 60068-2-6
Package Drop Test
ISTA 1A

Declaration

Green Product
RoHS, CRoHS, WEEE

MTBF

Time
NPort 5610-8-DT-G2: 29,666 hrs NPort 5610-8-DT-G2-T: 2,729,079 hrs NPort 5650-8-DT-G2: 29,612 hrs NPort 5650-8-DT-G2-T: 2,339,917 hrs NPort 5650I-8-DT-G2: 29,543 hrs NPort 5650I-8-DT-G2-T: 1,971,992 hrs NPort 5610-16-DT-J-G2 models: 2,043,468 hrs NPort 5650-16-DT-J-G2 models: 1,638,263 hrs NPort 5610-8-DTS-J-G2 models: 3,499,034 hrs NPort 5650-8-DTS-J-G2 models: 2,883,685 hrs
Standards
Telcordia Standard SR-332 Telcordia SR-332 Standard Issue 4

Warranty

Warranty Period
5 years
Details
See www.moxa.com/warranty

Resources

NameTypeVersionDate
Private MIB for NPort 5600-DT-G2 Series148.2 KBSoftware Packagev1.0.0May 27, 2026 May 27, 2026 Release notes
Firmware for NPort 5600-DT-G2 Series3.0 MBFirmwarev1.0.0May 27, 2026 May 27, 2026 Release notes
Moxa CLI Configuration Tool (Linux)11.3 MBUtilityv1.6Feb 02, 2026 Feb 02, 2026 Release notes
Moxa CLI Configuration Tool (Windows)2.1 MBUtilityv1.6Feb 02, 2026 Feb 02, 2026 Release notes
Real TTY Linux Kernel 5.x Driver650.0 KBDriverv5.6Jan 22, 2026 Jan 22, 2026 Release notes
Real TTY Linux Kernel 6.x Driver2.5 MBDriverv6.2Jan 22, 2026 Jan 22, 2026 Release notes
Real TTY Linux Kernel 4.x Driver650.0 KBDriverv4.4Jan 22, 2026 Jan 22, 2026 Release notes
Moxa Windows Driver Manager (Windows 11 and Server 2022 and later, WHQL certified)11.9 MBDriverv4.5Jan 09, 2026 Jan 09, 2026 Release notes
Device Search Utility (portable)128.6 MBUtilityv3.1Nov 17, 2025 Nov 17, 2025 Release notes
Device Search Utility (installer)236.2 MBUtilityv3.1Nov 17, 2025 Nov 17, 2025 Release notes
Serial Device Server Driver for macOS (macOS 11.x to 14)6.3 MBDriverv1.3Sep 02, 2024 Sep 02, 2024 Release notes
Tech Note: Secure Real COM Certificate Deployment For NPort G2 Models654.6 KBTech Notev1.0Aug 27, 2026
Tech Note: RADIUS Login Authentication With FreeRADIUS and Google Authenticator722.0 KBTech Notev1.0Jul 08, 2026
Datasheet for NPort 5600-DT-G2 Series2.1 MBDatasheetv1.1Jul 03, 2026
Tech Note: Creating Self-signed Certificate for Trusted HTTPS Connection525.3 KBTech Notev1.0Jul 02, 2026
Tech Note: The Migration Guide for the NPort 5600-DT Series1.9 MBTech Notev1.0May 27, 2026
Manual for NPort 5600-DT-G2 Series11.4 MBManualv1.0May 27, 2026
Tech Note: The Security Hardening Guide for the NPort 5600-DT-G2 Series1.2 MBTech Notev1.0May 27, 2026
QIG for NPort 5600-DT-G2 Series2.5 MBQIGv1.0May 22, 2026
FOSS Statement for Moxa CLI Configuration Tool114.6 KBDeclarationv1.0Dec 10, 2024
FOSS Statement for Device Search Utility161.8 KBDeclarationv1.0Jun 24, 2024
Tech Note: Moxa Real TTY Driver Porting Guide for Arm-based Platforms372.3 KBTech Notev2.0Jun 08, 2023
Tech Note: Real TTY Driver for NPort379.2 KBTech Notev2.0Jun 08, 2023
FOSS Statement for Moxa Windows Driver Manager255.8 KBDeclarationv1.0Aug 01, 2022

Need pricing on the NPort 5600-DT-G2 Series?

Tell us quantities and we'll come back with a quote.

Get a Quote