Moxa
IMC-101-S-SC-80

IMC-101-S-SC-80

IMC-101 Series

Industrial Ethernet-to-fiber media converters

  • 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
  • Link Fault Pass-Through (LFPT)
  • Power failure, port break alarm by relay output
  • Redundant power inputs
  • -40 to 75°C wide operating temperature range (-T models)
  • Designed for hazardous locations (Class 1 Div. 2/Zone 2, IECEx)

Certifications DNV · UL Listed · CE · FCC

Ships from and sold by A5 IT, an authorized Moxa reseller.

Specifications

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector)
1
100BaseFX Ports (single-mode SC connector)
1
Magnetic Isolation Protection
1.5 kV (built-in)
Optical Fiber
Read more 100BaseFX Multi-Mode Single-Mode (40 km) Single-Mode (80 km) Fiber Cable Type OM1 50/125 µm G.652 G.652 800 MHz x km Typical Distance 4 km 5 km 40 km 80 km Wavelength Typical (nm) 1300 1310 1550 TX Range (nm) 1260 to 1360 1280 to 1340 1530 to 1570 RX Range (nm) 1100 to 1600 1100 to 1600 1100 to 1600 Optical Power TX Range (dBm) -10 to -20 0 to -5 0 to -5 RX Range (dBm) -3 to -32 -3 to -34 -3 to -34 Link Budget (dB) 12 29 29 Dispersion Penalty (dB) 3 1 1 Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power. Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).

Power Parameters

Input Current
200 mA @ 12 to 45 VDC
Input Voltage
12 to 45 VDC
Overload Current Protection
Supported
Power Connector
Terminal block
Power Consumption
200 mA @ 12 to 45 VDC

Physical Characteristics

IP Rating
IP30
Housing
Metal
Dimensions
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight
630 g (1.39 lb)
Installation
DIN-rail mounting

Environmental Limits

Operating Temperature
0 to 60°C (32 to 140°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)

Standards and Certifications

EMC
EN 55032/35
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-11
Hazardous Locations
ATEX Zone 2 UL/cUL Class I Division 2 Groups A/B/C/D
Maritime
DNV
Safety
UL 60950-1 UL 508
Vibration
IEC 60068-2-6 IEC 60068-2-64
Shock
IEC 60068-2-27
Environmental Testing
IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-3
Freefall
IEC 60068-2-31 ISTA 2A

MTBF

Time
401,000 hrs
Standards
MIL-HDBK-217F

Warranty

Warranty Period
5 years
Details
See www.moxa.com/warranty

Documentation

NameTypeVersionDate
Datasheet for IMC-101 Series802.0 KBDatasheetv2.0Feb 03, 2026
Declaration of Conformity for IMC-101 Series302.7 KBDeclarationv1.0Mar 11, 2024
QIG for IMC-101 Series2.2 MBQIGv9.4Mar 01, 2023
2D CAD for IMC-101-MST TOP474.1 KB2D CADMar 28, 2017
2D CAD for IMC-101-IEX TOP223.5 KB2D CADMar 28, 2017
2D CAD for IMC-101257.4 KB2D CADMar 28, 2017
2D CAD for IMC-101-S-SC253.9 KB2D CADMar 28, 2017
2D CAD for IMC-101-M-SC253.9 KB2D CADMar 28, 2017