EDS-2010-ML-2GTXSFP-T
EDS-2010-ML Series8 FE, 2 1GbE-port unmanaged Ethernet switches
- 2 Gigabit uplinks with flexible interface design for high-bandwidth data aggregation
- QoS supported to process critical data in heavy traffic
- Relay output warning for power failure and port break alarm
- IP30-rated metal housing
- Redundant dual 12/24/48 VDC power inputs
- -40 to 75°C wide operating temperature range (-T models)
Certifications DNV · Iecex · CE · FCC
Ships from and sold by A5 IT, an authorized Moxa reseller.
Specifications
Ethernet Interface
- 10/100BaseT(X) Ports (RJ45 connector)
- 8 Auto negotiation speed Full/Half duplex mode Auto MDI/MDI-X connection
- Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+)
- 2 Auto negotiation speed Auto MDI/MDI-X connection Full/Half duplex mode
- Standards
- IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX IEEE 802.3x for flow control IEEE 802.1p for Class of Service
DIP Switch Configuration
- Ethernet Interface
- Quality of Service (QoS) Broadcast storm protection Port break alarm
Input/Output Interface
- Alarm Contact Channels
- Relay output with current carrying capacity of 1 A @ 24 VDC
Switch Properties
- MAC Table Size
- 8 K
- Packet Buffer Size
- 4 Mbits
- Processing Type
- Store and Forward
Power Parameters
- Connection
- 1 removable 6-contact terminal block(s)
- Input Current
- 0.251 A @ 24 VDC
- Input Voltage
- 12/24/48 VDC Redundant dual inputs
- Operating Voltage
- 9.6 to 60 VDC
- Overload Current Protection
- Supported
- Reverse Polarity Protection
- Supported
Physical Characteristics
- Housing
- Metal
- IP Rating
- IP30
- Dimensions
- 36 x 135 x 95 mm (1.41 x 5.31 x 3.74 in)
- Weight
- 498 g (1.10 lb)
- Installation
- DIN-rail mounting Wall mounting (with optional kit)
Environmental Limits
- Operating Temperature
- -40 to 75°C (-40 to 167°F)
- Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
- Safety
- UL 61010-2-201 EN 62368-1(LVD)
- EMC
- EN 55032/35 EN 61000-6-2/-6-4
- EMI
- CISPR 32, FCC Part 15B Class A
- EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
- Hazardous Locations
- Class I Division 2 ATEX IECEx
- Maritime
- DNV LR ABS NK
- Railway
- EN 50121-4
- Traffic Control
- NEMA TS2
- Vibration
- IEC 60068-2-6
- Shock
- IEC 60068-2-27
- Freefall
- IEC 60068-2-32
MTBF
- Time
- 2,174,016 hrs
- Standards
- Telcordia (Bellcore), GB
Warranty
- Warranty Period
- 5 years
- Details
- See www.moxa.com/warranty
Documentation
| Name | Type | Version | Date |
|---|---|---|---|
| Datasheet for EDS-2010-ML Series964.0 KB | Datasheet | v2.1 | Aug 26, 2025 |
| Declaration of Conformity (EU/UK) for EDS-2010/2018-ML Series313.3 KB | Declaration | v1.0 | Nov 04, 2024 |
| QIG for EDS-2010/2018-ML Series2.4 MB | QIG | v1.5 | Jan 10, 2023 |
| 2D CAD for EDS-2010-ML Series751.3 KB | 2D CAD | — | Sep 11, 2019 |
| Tech Note: Recommended Procedure for STP Cable Grounding on Moxa's Industrial Ethernet Switches558.3 KB | Tech Note | v1.0 | Nov 16, 2016 |