EDS-2016-ML-MM-ST
EDS-2016-ML Series16 FE-port unmanaged Ethernet switches
- 10/100BaseT(X) (RJ45 connector), 100BaseFX (multi/single-mode, SC or ST connector)
- QoS supported to process critical data in heavy traffic
- Relay output warning for power failure and port break alarm
- IP30-rated metal housing
- Redundant dual 12/24/48 VDC power inputs
- -40 to 75°C operating temperature range (-T model)
Certifications DNV · Iecex · CE · FCC
Ships from and sold by A5 IT, an authorized Moxa reseller.
Specifications
Ethernet Interface
- 10/100BaseT(X) Ports (RJ45 connector)
- 14
- 100BaseFX Ports (multi-mode ST connector)
- 2
- Standards
- IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for flow control IEEE 802.1p for Class of Service
- Optical Fiber
- Read more 100BaseFX Multi-Mode Single-Mode (40 km) Single-Mode (80 km) Fiber Cable Type OM1 50/125 µm G.652 G.652 800 MHz x km Typical Distance 4 km 5 km 40 km 80 km Wavelength Typical (nm) 1300 1310 1550 TX Range (nm) 1260 to 1360 1280 to 1340 1530 to 1570 RX Range (nm) 1100 to 1600 1100 to 1600 1100 to 1600 Optical Power TX Range (dBm) -10 to -20 0 to -5 0 to -5 RX Range (dBm) -3 to -32 -3 to -34 -3 to -34 Link Budget (dB) 12 29 29 Dispersion Penalty (dB) 3 1 1 Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power. Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).
DIP Switch Configuration
- Ethernet Interface
- Quality of Service (QoS) Broadcast storm protection Port break alarm
Input/Output Interface
- Alarm Contact Channels
- Relay output with current carrying capacity of 1 A @ 24 VDC
Switch Properties
- MAC Table Size
- 8 K
- Packet Buffer Size
- 2 Mbits
- Processing Type
- Store and Forward
Power Parameters
- Connection
- 1 removable 6-contact terminal block(s)
- Input Current
- 0.152 A @ 24 VDC
- Input Voltage
- 12/24/48 VDC Redundant dual inputs
- Operating Voltage
- 9.6 to 60 VDC
- Overload Current Protection
- Supported
- Reverse Polarity Protection
- Supported
Physical Characteristics
- Housing
- Metal
- IP Rating
- IP30
- Dimensions
- 58 x 135 x 95 mm (2.28 x 5.31 x 3.74 in)
- Weight
- 648 g (1.43 lb)
- Installation
- DIN-rail mounting Wall mounting (with optional kit)
Environmental Limits
- Operating Temperature
- -10 to 60°C (14 to 140°F)
- Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
- Safety
- UL 61010-2-201 EN 62368-1(LVD)
- EMC
- EN 55032/35 EN 61000-6-2/-6-4
- EMI
- CISPR 32, FCC Part 15B Class A
- EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
- Hazardous Locations
- Class I Division 2 ATEX IECEx
- Railway
- EN 50121-4
- Traffic Control
- NEMA TS2
- Vibration
- IEC 60068-2-6
- Shock
- IEC 60068-2-27
- Freefall
- IEC 60068-2-32
- Maritime
- DNV LR ABS NK
MTBF
- Time
- 2,070,826 hrs
- Standards
- Telcordia (Bellcore), GB
Warranty
- Warranty Period
- 5 years
- Details
- See www.moxa.com/warranty
Documentation
| Name | Type | Version | Date |
|---|---|---|---|
| Datasheet for EDS-2016-ML Series1.6 MB | Datasheet | v2.3 | Aug 26, 2025 |
| 2D CAD for EDS-2016-ML Series2.7 MB | 2D CAD | — | Aug 04, 2025 |
| Declaration of Conformity (EU/UK) for EDS-2016-ML Series315.0 KB | Declaration | v1.0 | Jan 14, 2025 |
| QIG for EDS-2016-ML Series3.8 MB | QIG | v1.5 | Jul 10, 2023 |
| Tech Note: Recommended Procedure for STP Cable Grounding on Moxa's Industrial Ethernet Switches558.3 KB | Tech Note | v1.0 | Nov 16, 2016 |