Moxa
EDS-2016-ML-SS-SC

EDS-2016-ML-SS-SC

EDS-2016-ML Series

16 FE-port unmanaged Ethernet switches

  • 10/100BaseT(X) (RJ45 connector), 100BaseFX (multi/single-mode, SC or ST connector)
  • QoS supported to process critical data in heavy traffic
  • Relay output warning for power failure and port break alarm
  • IP30-rated metal housing
  • Redundant dual 12/24/48 VDC power inputs
  • -40 to 75°C operating temperature range (-T model)

Certifications DNV · Iecex · CE · FCC

Ships from and sold by A5 IT, an authorized Moxa reseller.

Specifications

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector)
14
100BaseFX Ports (multi-mode SC connector)
2
100BaseFX Ports (single-mode SC connector)
2
Standards
IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for flow control IEEE 802.1p for Class of Service
Optical Fiber
Read more 100BaseFX Multi-Mode Single-Mode (40 km) Single-Mode (80 km) Fiber Cable Type OM1 50/125 µm G.652 G.652 800 MHz x km Typical Distance 4 km 5 km 40 km 80 km Wavelength Typical (nm) 1300 1310 1550 TX Range (nm) 1260 to 1360 1280 to 1340 1530 to 1570 RX Range (nm) 1100 to 1600 1100 to 1600 1100 to 1600 Optical Power TX Range (dBm) -10 to -20 0 to -5 0 to -5 RX Range (dBm) -3 to -32 -3 to -34 -3 to -34 Link Budget (dB) 12 29 29 Dispersion Penalty (dB) 3 1 1 Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power. Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).

DIP Switch Configuration

Ethernet Interface
Quality of Service (QoS) Broadcast storm protection Port break alarm

Input/Output Interface

Alarm Contact Channels
Relay output with current carrying capacity of 1 A @ 24 VDC

Switch Properties

MAC Table Size
8 K
Packet Buffer Size
2 Mbits
Processing Type
Store and Forward

Power Parameters

Connection
1 removable 6-contact terminal block(s)
Input Current
0.163 A @ 24 VDC
Input Voltage
12/24/48 VDC Redundant dual inputs
Operating Voltage
9.6 to 60 VDC
Overload Current Protection
Supported
Reverse Polarity Protection
Supported

Physical Characteristics

Housing
Metal
IP Rating
IP30
Dimensions
58 x 135 x 95 mm (2.28 x 5.31 x 3.74 in)
Weight
648 g (1.43 lb)
Installation
DIN-rail mounting Wall mounting (with optional kit)

Environmental Limits

Operating Temperature
-10 to 60°C (14 to 140°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)

Standards and Certifications

Safety
UL 61010-2-201 EN 62368-1(LVD)
EMC
EN 55032/35 EN 61000-6-2/-6-4
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
Hazardous Locations
Class I Division 2 ATEX IECEx
Railway
EN 50121-4
Traffic Control
NEMA TS2
Vibration
IEC 60068-2-6
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Maritime
DNV LR ABS NK

MTBF

Time
2,070,826 hrs
Standards
Telcordia (Bellcore), GB

Warranty

Warranty Period
5 years
Details